Temperature and Pressure Case + AI EVOLUTION

This overhead case was specially designed and built to meet the needs of a well-known automotive company. The company required a NATIONAL INSTRUMENTATION acquisition system to manage 36 temperature channels, 24 analog channels, 6 COUNTER inputs, and various other functions that we will now describe.

 

Complete overhead metal case:

FRONT

10 aluminum panels prepared to house:

     - 24 three-pole connectors for K-type temperatures

     - 12 three-pole connectors for PT100 temperatures

     - 6 BNC sockets and some power sockets

     - 24 voltage inputs with 6-pole PHOENIX connectors

     - 4 digital outputs with 3-pole PHOENIX connectors

     - 4 digital inputs with 2-pole PHOENIX connectors

     - 2 COUNT IN inputs with 9-pin female D-sub connectors

     - 4 free COUNT IN inputs with 9-pin male D-sub connectors

1 Power panel: +5, +12, +24

1 Panel with MOTOR STOP mushroom button and two D-sub connectors for DA outputs

Panel including: 4 USB sockets connected via a HUB to your data acquisition and management PC, 1 USB socket connected to the internal acquisition system, and 2 ETHERNET sockets

 

SIDE

Mounting systems for 16 pressure sensors